Carlo Gavazzi
RGC1P23V30ED1P-SSC V IN - PS 230V 30A 800VP-E
1P-SSC V IN - PS 230V 30A 800VP-E
Solid State / Static Relay (SSR) with integrated heatsnk. + analog control input 0-5Vdc / 1-5Vdc / 0-10Vdc + contact. connection configuration - Carlo Gavazzi (RGC1P series) - Output 30A (AC; 1800A²s) / 85Vac-265Vac (230Vac nom.) - phase-angle control OR full-cycle output switching / optional soft-starting (with 0...5s adjustable time) - single-pole / single-phase / 1-pole (1P) - Supply voltage 24Vac (external supply) / 24Vdc (external supply) - screw connections (pwr. connections) - DIN rail mounting (35mm width)
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
RGC1P23V30ED
Net Price
$217.51
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Minimum quantity may be required
Carlo Gavazzi - RGC1P-VRGC1P23V30ED
Description
Solid State / Static Relay (SSR) with integrated heatsnk. + analog control input 0-5Vdc / 1-5Vdc / 0-10Vdc + contact. connection configuration - Carlo Gavazzi (RGC1P series) - Output 30A (AC; 1800A²s) / 85Vac-265Vac (230Vac nom.) - phase-angle control OR full-cycle output switching / optional soft-starting (with 0...5s adjustable time) - single-pole / single-phase / 1-pole (1P) - Supply voltage 24Vac (external supply) / 24Vdc (external supply) - screw connections (pwr. connections) - DIN rail mounting (35mm width)
Additional Information
Solid state / static relay (SSR) - Single phase - Carlo Gavazzi (RGC1P) - Rated current 30A - Control voltage 0-10Vdc / 0-5Vdc /1-5Vdc - Rated voltage 85-265Vac. 1027154 RGC1P23V30ED #instock
Specifications
Primary brand
Carlo Gavazzi
Main function
Solid State Relay (SSR)
Product series / family name
RGC1P series
Functions
Solid State / Static Relay (SSR)
Design
integrated heatsnk.
analog control input 0-5Vdc / 1-5Vdc / 0-10Vdc
contact. connection configuration
phase-angle control OR full-cycle output switching
optional soft-starting (with 0...5s adjustable time)
analog control input 0-5Vdc / 1-5Vdc / 0-10Vdc
contact. connection configuration
phase-angle control OR full-cycle output switching
optional soft-starting (with 0...5s adjustable time)
Poles
single-pole / single-phase / 1-pole (1P)
Supply voltage (AC)
24Vac (external supply)
Supply voltage (DC)
24Vdc (external supply)
Display
green LED indicator (control-ON)
yellow LED indicator (load-ON)
yellow LED indicator (load-ON)
Rated current
30A (AC; 1800A²s)
30A (AC at Ta = 40°C; AC-51; induction-free or slightly inductive loads / resistance furnaces)
30A (AC at Ta = 40°C; AC-55b; switching incandescent lamps)
Minimum operational current 250mA (AC). Relay output will not conduct below this value
Repeating overload current t-on=1s t-off=9s 84A (AC)
Maximum transient surge current t=10ms 600Apeak
Minimum I²t for fusing t=10ms ≤1800A²s
30A (AC at Ta = 40°C; AC-51; induction-free or slightly inductive loads / resistance furnaces)
30A (AC at Ta = 40°C; AC-55b; switching incandescent lamps)
Minimum operational current 250mA (AC). Relay output will not conduct below this value
Repeating overload current t-on=1s t-off=9s 84A (AC)
Maximum transient surge current t=10ms 600Apeak
Minimum I²t for fusing t=10ms ≤1800A²s
Rated voltage (AC)
85Vac-265Vac (230Vac nom.) output voltage
45-65Hz
PF / cos phi ≥0.7 (inductive load)
800Vac (Vp; output blocking voltage)
Rated impulse withstand voltage; Uimp 6kV (1.5/50μs)
Overvoltage protection 32Vac/dc for 30s
45-65Hz
PF / cos phi ≥0.7 (inductive load)
800Vac (Vp; output blocking voltage)
Rated impulse withstand voltage; Uimp 6kV (1.5/50μs)
Overvoltage protection 32Vac/dc for 30s
Connection type
screw connections (pwr. connections)
Control Voltage (DC)
Control input 0-5Vdc (A1-GND) / 1-5Vdc (A2-GND) / 0-10Vdc (A3-GND)
Pick-up voltage 0.5Vdc (A1-GND/A3-GND); 1.5Vdc (A2-GND)
Drop-out voltage 0.05Vdc (A1-GND/A3-GND); 1.02Vdc (A2-GND)
Control input impedance 100kΩ
Pick-up voltage 0.5Vdc (A1-GND/A3-GND); 1.5Vdc (A2-GND)
Drop-out voltage 0.05Vdc (A1-GND/A3-GND); 1.02Vdc (A2-GND)
Control input impedance 100kΩ
Mounting mode
DIN rail mounting
Speed
Max. input response time (input to output) 2-half-cycles (modes 1/5/7); 3-half-cycles (2/3/4/6)
Critical dV/dt 1000V/μs
Critical dV/dt 1000V/μs
Degree of protection
IP20
Dimensions
35mm width
Order code / Manufacturer SKU
RGC1P23V30ED
Manufacturer product status
Commercialized
Compliant with standard(s)
EN/IEC 60947-4-3
UL 508 Listed (E172877; NMFT)
cUL Listed (CSA 22.2 No.14-13; E172877; NMFT7)
CE
EAC
UL 508 Listed (E172877; NMFT)
cUL Listed (CSA 22.2 No.14-13; E172877; NMFT7)
CE
EAC
Benefits
The RGC1P is a series of solid state contactors (with integrated heatsink) that give the possibility to control output power of 1-phase loads with an analog control input.
Input types cover a wide range of current and voltage ranges.
Local setting by an external potentiometer is possible.
Switching modes selectable through a front knob allow phase angle control full cycle control advanced full cycle control specific for short wave infrared heaters and soft starting for limiting inrush current of loads having a high temperature coefficient.
The output of the RGC1P is protected against overvoltage by means of an integrated varistor across the output.
Two front LEDs indicate the status of the load and control.
Specifications are at a surrounding temperature of 25°C unless otherwise specified.
Input types cover a wide range of current and voltage ranges.
Local setting by an external potentiometer is possible.
Switching modes selectable through a front knob allow phase angle control full cycle control advanced full cycle control specific for short wave infrared heaters and soft starting for limiting inrush current of loads having a high temperature coefficient.
The output of the RGC1P is protected against overvoltage by means of an integrated varistor across the output.
Two front LEDs indicate the status of the load and control.
Specifications are at a surrounding temperature of 25°C unless otherwise specified.
Degree of pollution
2