Carlo Gavazzi
RGC3A60A65GGEAF3P -SSC-AC IN-ZC 600V 3X65A 1200VP-E-CLP IN OTP
3P -SSC-AC IN-ZC 600V 3X65A 1200VP-E-CLP IN OTP
Solid State / Static Relay (SSR) with integrated heatsnk. + integrated fan + contact. connection configuration + EMR alarm output - Carlo Gavazzi (RGC3 series) - Output 65A (AC; 15000A²s) / 42Vac-660Vac (600Vac nom.) - zero-cross switching (ZC) - 20-275Vac (24Vac / 120Vac / 220Vac / 240Vac nom.) control voltage - 3-switching poles (3P) - Supply voltage 90-250Vac (110Vac / 120Vac / 240Vac nom.; external supply) - box-clamp connections (control & pwr. connections) - DIN rail mounting (70mm width) - with over-temperature protection
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
RGC3A60A65GGEAF
Net Price
$620.46
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Minimum quantity may be required
Carlo Gavazzi - RGC3-A65-AFRGC3A60A65GGEAF
Description
Solid State / Static Relay (SSR) with integrated heatsnk. + integrated fan + contact. connection configuration + EMR alarm output - Carlo Gavazzi (RGC3 series) - Output 65A (AC; 15000A²s) / 42Vac-660Vac (600Vac nom.) - zero-cross switching (ZC) - 20-275Vac (24Vac / 120Vac / 220Vac / 240Vac nom.) control voltage - 3-switching poles (3P) - Supply voltage 90-250Vac (110Vac / 120Vac / 240Vac nom.; external supply) - box-clamp connections (control & pwr. connections) - DIN rail mounting (70mm width) - with over-temperature protection
Additional Information
Solid state / static relay (SSR) - 3-phase - Carlo Gavazzi (RGC3) - Rated current 65A - Control voltage 20-275Vac - Rated voltage 600Vac - DIN Rail Mount. 1021562 RGC3A60A65GGEAF 670000546 #instock
Specifications
Primary brand
Carlo Gavazzi
Main function
Solid State Relay (SSR)
Product series / family name
RGC3 series
Functions
Solid State / Static Relay (SSR)
Design
integrated heatsnk.
integrated fan
contact. connection configuration
EMR alarm output
zero-cross switching (ZC)
integrated fan
contact. connection configuration
EMR alarm output
zero-cross switching (ZC)
Poles
3-switching poles (3P)
Supply voltage (AC)
90-250Vac (110Vac / 120Vac / 240Vac nom.; external supply)
Display
green LED indicator (control-ON)
yellow LED indicator (load-ON)
red LED indicator (alarm-ON)
yellow LED indicator (load-ON)
red LED indicator (alarm-ON)
Rated current
65A (AC; 15000A²s)
66A (AC at Ta = 40°C; AC-51; induction-free or slightly inductive loads / resistance furnaces)
25A (AC at Ta = 40°C; AC-53a; control of a squirrel cage motor; 8-hour operation with starting currents for starting processes / maneuvering / operation)
Minimum operational current 500mA (AC). Relay output will not conduct below this value
Repeating overload current t-on=1s t-off=9s 154A (AC)
Maximum transient surge current t=10ms 1750Apeak
Minimum I²t for fusing t=10ms ≤15000A²s
66A (AC at Ta = 40°C; AC-51; induction-free or slightly inductive loads / resistance furnaces)
25A (AC at Ta = 40°C; AC-53a; control of a squirrel cage motor; 8-hour operation with starting currents for starting processes / maneuvering / operation)
Minimum operational current 500mA (AC). Relay output will not conduct below this value
Repeating overload current t-on=1s t-off=9s 154A (AC)
Maximum transient surge current t=10ms 1750Apeak
Minimum I²t for fusing t=10ms ≤15000A²s
Rated voltage (AC)
42Vac-660Vac (600Vac nom.) output voltage
45-65Hz
PF / cos phi ≥0.5 (inductive load)
1200Vac (Vp; output blocking voltage)
ON-state voltage drop ≤2Vac (at rated current)
Rated impulse withstand voltage; Uimp 6kV (1.5/50μs)
45-65Hz
PF / cos phi ≥0.5 (inductive load)
1200Vac (Vp; output blocking voltage)
ON-state voltage drop ≤2Vac (at rated current)
Rated impulse withstand voltage; Uimp 6kV (1.5/50μs)
Connection type
box-clamp connections (control & pwr. connections)
Control Voltage (AC)
20-275Vac (24Vac / 120Vac / 220Vac / 240Vac nom.)
Control Voltage (DC)
Pick-up voltage 20Vac
Drop-out voltage 5Vac
Drop-out voltage 5Vac
Protection functions
over-temperature protection
Mounting mode
DIN rail mounting
Speed
Max. response time 5 cycles at 230Vac
Critical dV/dt 1000V/μs
Critical dV/dt 1000V/μs
Digital outputs
1 x digital output (SPDT / Form C rly. contact; 2A at 250Vac / 30Vdc) (alarm output)
Degree of protection
IP20
Dimensions
70mm width
Order code / Manufacturer SKU
RGC3A60A65GGEAF
Manufacturer product status
Commercialized
Compliant with standard(s)
LVD (EN/IEC 60947-4-2; EN/IEC 60947-4-3)
EMCD (EN 60947-4-3)
UL 508 Listed (E172877)
cUL (C22.2 No.14-13; E172877)
CCC; GB/T 14048.5-2017 (IEC 60947-5-1)
VDE 0660-117 (DIN EN 60947-4-2)
CE
EAC
EMCD (EN 60947-4-3)
UL 508 Listed (E172877)
cUL (C22.2 No.14-13; E172877)
CCC; GB/T 14048.5-2017 (IEC 60947-5-1)
VDE 0660-117 (DIN EN 60947-4-2)
CE
EAC
Benefits
This product is intended to replace mechanical contactors especially when switching is frequent.
The smallest product width in the RGC2 RGC3 range is 54mm (3xDIN) and goes up to 70mm.
2-pole and 3-pole switching options are available.
Apart from resistive and slightly inductive loads the RGC is certified for motor switching with associated motor ratings.
A green LED gives indication of control voltage presence.
Fan operation is controlled for the versions which have an integrated fan.
Detection of SSR overheat mains loss SSR malfunction and load loss is possible with the RGC..M versions.
An EMR alarm output is available for remote signaling.
An additional feature with the RGC..M is the electronic auxiliary output.
The RGC..M has additional LEDs for load status and alarm status indication.
The smallest product width in the RGC2 RGC3 range is 54mm (3xDIN) and goes up to 70mm.
2-pole and 3-pole switching options are available.
Apart from resistive and slightly inductive loads the RGC is certified for motor switching with associated motor ratings.
A green LED gives indication of control voltage presence.
Fan operation is controlled for the versions which have an integrated fan.
Detection of SSR overheat mains loss SSR malfunction and load loss is possible with the RGC..M versions.
An EMR alarm output is available for remote signaling.
An additional feature with the RGC..M is the electronic auxiliary output.
The RGC..M has additional LEDs for load status and alarm status indication.
Degree of pollution
2
Related Documents
Name | Last Update | Language |
---|---|---|
Carlo Gavazzi - SSR - RGC2A - RGC3A.pdf | 12 Sep 2021 | English (US) |