Carlo Gavazzi
RM1A60D50SSR ZS 600V 50A 4.5-32VDC LED
SSR ZS 600V 50A 4.5-32VDC LED
Solid State / Static Relay (SSR) with clip-on IP20 protection cover + built-in varistor + housing free of moulding mass - Carlo Gavazzi (RM series) - Output 50A (AC; RMS) / 42Vac-660Vac (600Vac nom. RMS) - zero switching (ZS) - 4-32Vdc (5Vdc / 6Vdc / 12Vdc / 24Vdc nom.) control voltage - single-pole / single-phase / 1-pole (1P) - self-lifting screw-clamp term. connections
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
RM1A60D50
Please add this item to cart to request a quote.
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Minimum quantity may be required
Carlo Gavazzi - RM-60-50RM1A60D50
Description
Solid State / Static Relay (SSR) with clip-on IP20 protection cover + built-in varistor + housing free of moulding mass - Carlo Gavazzi (RM series) - Output 50A (AC; RMS) / 42Vac-660Vac (600Vac nom. RMS) - zero switching (ZS) - 4-32Vdc (5Vdc / 6Vdc / 12Vdc / 24Vdc nom.) control voltage - single-pole / single-phase / 1-pole (1P) - self-lifting screw-clamp term. connections
Additional Information
Solid state / static relay (SSR) - Single phase - Carlo Gavazzi (RM) - Rated current 50A - Control voltage 4-32Vdc - Rated voltage 600Vac. 1025109 RM1A60D50 #instock
Specifications
Primary brand
Carlo Gavazzi
Main function
Solid State Relay (SSR)
Product series / family name
RM series
Functions
Solid State / Static Relay (SSR)
Design
clip-on IP20 protection cover
built-in varistor
housing free of moulding mass
direct Copper bonding technology
zero switching (ZS)
built-in varistor
housing free of moulding mass
direct Copper bonding technology
zero switching (ZS)
Poles
single-pole / single-phase / 1-pole (1P)
Display
LED indicator
Rated current
50A (AC; RMS)
50A (RMS; AC-51; induction-free or slightly inductive loads / resistance furnaces)
15A (RMS; AC-53a; control of a squirrel cage motor; 8-hour operation with starting currents for starting processes / maneuvering / operation)
Minimum operational current 250mA (AC). Relay output will not conduct below this value
Repeating overload current t=1s ≤125A RMS
Non-repeating surge current t=10ms 600Apeak
OFF-state leakage current ≤3mA RMS (at rated voltage and frequency)
Minimum I²t for fusing t=10ms ≤1800A²s
50A (RMS; AC-51; induction-free or slightly inductive loads / resistance furnaces)
15A (RMS; AC-53a; control of a squirrel cage motor; 8-hour operation with starting currents for starting processes / maneuvering / operation)
Minimum operational current 250mA (AC). Relay output will not conduct below this value
Repeating overload current t=1s ≤125A RMS
Non-repeating surge current t=10ms 600Apeak
OFF-state leakage current ≤3mA RMS (at rated voltage and frequency)
Minimum I²t for fusing t=10ms ≤1800A²s
Rated voltage (AC)
42Vac-660Vac (600Vac nom. RMS) output voltage
45-65Hz
PF / cos phi ≥0.5 (inductive load)
1400Vac (Vp; output blocking voltage)
Zero voltage turn-on ≤10Vac
OPTO-isolation ≥4000Vac RMS
45-65Hz
PF / cos phi ≥0.5 (inductive load)
1400Vac (Vp; output blocking voltage)
Zero voltage turn-on ≤10Vac
OPTO-isolation ≥4000Vac RMS
Connection type
self-lifting screw-clamp term. connections
Control Voltage (DC)
4-32Vdc (5Vdc / 6Vdc / 12Vdc / 24Vdc nom.)
Pick-up voltage 3.5Vdc
Drop-out voltage 1.2Vdc
Max. reverse voltage 32Vdc
Pick-up voltage 3.5Vdc
Drop-out voltage 1.2Vdc
Max. reverse voltage 32Vdc
Mounting mode
direct screw mounting on surface
Speed
Input response time (pick-up) ≤1/2 cycle
Input response time (drop-out) ≤1/2 cycle
Endurance testing according to UL 508 100000 cycles
Critical dV/dt 1000V/μs
Input response time (drop-out) ≤1/2 cycle
Endurance testing according to UL 508 100000 cycles
Critical dV/dt 1000V/μs
Dimensions
W45mm x H58mm x D29mm
Order code / Manufacturer SKU
RM1A60D50
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60947-4-3
UL 508 Listed
UR
cUR
CSA
CCC
CE
EAC
UL 508 Listed
UR
cUR
CSA
CCC
CE
EAC
Benefits
The industrial 1-phase relay with antiparallel thyristor output is the most widely used industrial SSR due to its multiple application possibilities.
The relay can be used for resistive inductive and capacitive loads.
The zero switching relay switches ON when the sinusoidal curve crosses zero and switches OFF when the current crosses zero.
The instant-on relay with DC control input can be used for phase control.
The built-in varistor secures transient protection for the heavy industrial applications and the LED indicates the status of the control input.
The clip-on cover is securing touch protection to IP20.
Protected output terminals can handle cables up to 16mm2.
The relay can be used for resistive inductive and capacitive loads.
The zero switching relay switches ON when the sinusoidal curve crosses zero and switches OFF when the current crosses zero.
The instant-on relay with DC control input can be used for phase control.
The built-in varistor secures transient protection for the heavy industrial applications and the LED indicates the status of the control input.
The clip-on cover is securing touch protection to IP20.
Protected output terminals can handle cables up to 16mm2.
Related Documents
Name | Last Update | Language |
---|---|---|
Carlo Gavazzi - SSR - RM1.pdf | 12 Sep 2021 | English (US) |