Red Lion
T4832210
Digital temperature controller with triac main output + 1 logic/S.S.R. alarm output + 1 logic/S.S.R. ALARM2 (or cooling) output - 1/16 DIN (48x48mm) - Red Lion (Process controllers T48 temperature controllers series) - with 1 x analog input (Thermocouple types T; E; J; K; R; S; B; N / Pt100 RTDs / 100ms sample period; 300-400ms response time) (Main temperature input; 0.1...1° accuracy) + 1 x digital output (S.S.R.) (Main output O1) + 1 x digital output (S.S.R.) (ALARM1) + 1 x digital output (S.S.R.) (O2 / ALARM2) - Supply voltage 24Vac / 18-36Vdc (24Vdc) - IP65 / NEMA 4X
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
T4832210
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
T4832210Red Lion - T48
Description
Digital temperature controller with triac main output + 1 logic/S.S.R. alarm output + 1 logic/S.S.R. ALARM2 (or cooling) output - 1/16 DIN (48x48mm) - Red Lion (Process controllers T48 temperature controllers series) - with 1 x analog input (Thermocouple types T; E; J; K; R; S; B; N / Pt100 RTDs / 100ms sample period; 300-400ms response time) (Main temperature input; 0.1...1° accuracy) + 1 x digital output (S.S.R.) (Main output O1) + 1 x digital output (S.S.R.) (ALARM1) + 1 x digital output (S.S.R.) (O2 / ALARM2) - Supply voltage 24Vac / 18-36Vdc (24Vdc) - IP65 / NEMA 4X
Specifications
Primary brand
Red Lion
Main function
Temperature controller (Digital)
Product series / family name
Process controllers
Sub-range name
T48 temperature controllers series
Functions
Digital temperature controller
Design
triac main output
1 logic/S.S.R. alarm output
1 logic/S.S.R. ALARM2 (or cooling) output
1/16 DIN (48x48mm)
1 logic/S.S.R. alarm output
1 logic/S.S.R. ALARM2 (or cooling) output
1/16 DIN (48x48mm)
Supply voltage (AC)
24Vac
Supply voltage (DC)
18-36Vdc (24Vdc)
Digital outputs
1 x digital output (S.S.R.) (Main output O1)
1 x digital output (S.S.R.) (ALARM1)
1 x digital output (S.S.R.) (O2 / ALARM2)
1 x digital output (S.S.R.) (ALARM1)
1 x digital output (S.S.R.) (O2 / ALARM2)
Analog inputs
1 x analog input (Thermocouple types T; E; J; K; R; S; B; N / Pt100 RTDs / 100ms sample period; 300-400ms response time) (Main temperature input; 0.1...1° accuracy)
Degree of protection
IP65
NEMA 4X
NEMA 4X
Dimensions
1/16 DIN (W48mm x H48mm / 1.89" x 1.89")
Order code / Manufacturer SKU
T4832210
Manufacturer product status
Phasing out
Compliant with standard(s)
CE
IEC/EN 61010-1
IEC 60068-2-6 (vibration)
EN 61326-1 immunity to industrial locations
UL recognized
RoHS compliant
IEC/EN 61010-1
IEC 60068-2-6 (vibration)
EN 61326-1 immunity to industrial locations
UL recognized
RoHS compliant
Benefits
PID control with reduced overshoot
On demand auto-tuning of PID control settings
NEMA 4x / IP65 bezel
Dual led displays for simultaneous indication of temperature and setpoint
Status indicators for outputs and control modes
Accepts 10 types of sensor inputs (thermocouple / RTD)
Optional heater current monitor and heater break alarm
Optional dual alarm outputs
Optional two linear DC outputs
Manual/automatic control modes
Setpoint ramping for process startup
Programmable user input (digital) for added flexibility
Sensor error compensation (offset) and break detection
Heating and optional cooling outputs
Parameter security via programmable lockouts
Field replaceable output board (relay / logic / SSR drive)
Optional triac output
Second setpoint setting
Optional remote setpoint input
Optional RS-485 serial communications
PC software available for controller configuration
On demand auto-tuning of PID control settings
NEMA 4x / IP65 bezel
Dual led displays for simultaneous indication of temperature and setpoint
Status indicators for outputs and control modes
Accepts 10 types of sensor inputs (thermocouple / RTD)
Optional heater current monitor and heater break alarm
Optional dual alarm outputs
Optional two linear DC outputs
Manual/automatic control modes
Setpoint ramping for process startup
Programmable user input (digital) for added flexibility
Sensor error compensation (offset) and break detection
Heating and optional cooling outputs
Parameter security via programmable lockouts
Field replaceable output board (relay / logic / SSR drive)
Optional triac output
Second setpoint setting
Optional remote setpoint input
Optional RS-485 serial communications
PC software available for controller configuration
Related Documents
Name | Last Update | Language |
---|---|---|
Red Lion - Industrial Automation Product Guide.pdf | 25 Apr 2021 | English (US) |
Red Lion - T48 P48 TLA Output Board - Product Manual.pdf | 25 Apr 2021 | English (US) |
Red Lion - T48 PID controllers - Datasheet.pdf | 25 Apr 2021 | English (US) |
Red Lion - T48-P48 - Instruction Manual.pdf | 25 Apr 2021 | English (US) |